Electronics Line 3208GLD User Manual Page 31

  • Download
  • Add to my manuals
  • Print
  • Page
    / 51
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 30
31
address 197). Note: When using the Follow-me feature, Ack1 is received when the user
presses 0, 9 or # on their telephone and Ack2 is not relevant.
Second digit value:
Time-Out Time-Out
Ack 1 Ack 2 Value Ack 1 Ack 2 Value
2 sec 0 2 sec 8
2 sec 3 sec 1 30 sec 3 sec 9
5 sec 2 5 sec A
10 sec 3 10 sec B
2 sec 4 2 sec C
15 sec 3 sec 5 60 sec 3 sec D
5 sec 6 5 sec E
10 sec 7 10 sec F
197 First Digit: Dialing & Message attempts
The first digit of this address deals with the number of times the panel attempts to dial or
transmit an event code message until a successful transmission is sent.
First digit value:
Dialing
Message
Value
Dialing
Message
Value
1 0 1 8
1 2 1 5 2 9
5 2 5 A
10 3 10 B
1 4 1 C
2 2 5 10 2 D
5 6 5 E
10 7 10 F
Second Digit: Dial Tone Wait and Anti Jamming
The default value for the second digit of this parameter has been chosen according to the
requirements of the local telecommunications authority. If any problems are experienced,
please contact Electronics Line Technical Support Dept.
Second digit value:
0 - Dial after 1 second, 2 second anti-jam
1 - Dial after 5 seconds, 2 second anti-jam
2 - Dial after 10 seconds, 2 second anti-jam
3 - Dial after 20 seconds, 2 second anti-jam
4 - Dial after 1 second or if dial tone present, 2 second anti-jam
5 - Dial after 5 seconds or if dial tone present, 2 second anti-jam
6 - Dial after 10 seconds or if dial tone present, 2 second anti-jam
7 - Dial after 20 seconds or if dial tone present, 2 second anti-jam
8 - Dial after 1 second, 10 second ant-jam
9 - Dial after 5 seconds, 10 second anti-jam
A - Dial after 10 seconds, 10 second anti-jam
B - Dial after 20 seconds, 10 second anti-jam
C - Dial after 1 second or if dial tone present, 10 second anti-jam
D - Dial after 5 seconds or if dial tone present, 10 second anti-jam
E - Dial after 10 seconds or if dial tone present, 10 second anti-jam
F - Dial after 20 seconds or if dial tone present, 10 second anti-jam
Page view 30
1 2 ... 26 27 28 29 30 31 32 33 34 35 36 ... 50 51

Comments to this Manuals

No comments